Solar Calculator Canada

Solar Power Calculator for Chandler, Quebec, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Chandler
  • GPS Coordinates: 48.35, -64.6833333
  • Elevation: 21 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technoloty: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Chandler: 41o
  • Average yearly irradiance: 1502.3 kWh/m2
  • Average yearly power output: 129085 kWh
Sun Path Chandler

Average yearly irradiance delivered by the Sun in Chandler is 1502.3/kWh/m2 at the optimal panel slope of 41o. After taking all losses into account, you can expect about 129085 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 41o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.74 85
February 3.64 101.86
March 4.59 142.3
April 5.05 151.65
May 5.22 161.88
June 5.24 157.3
July 5.39 167.12
August 5.11 158.42
September 4.59 137.6
October 3.47 107.48
November 2.43 73.01
December 1.89 58.68
Total yearly 1502.3

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 239.28 7417.66
February 314.53 8806.97
March 393.25 12190.6
April 431.09 12932.7
May 445.37 13806.3
June 448.1 13443
July 461.87 14317.9
August 437.96 13576.9
September 393.88 11816.4
October 300.24 9307.57
November 211.83 6354.78
December 164.96 5113.9
Total yearly 129085

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) fals between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Chandler solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 165.32 5125.04
February 243.2 6809.55
March 344.32 10673.8
April 420.37 12611.1
May 467.41 14489.6
June 485.56 14566.9
July 492.03 15253
August 440.78 13664.1
September 358.64 10759.3
October 245.06 7596.86
November 153.66 4609.91
December 112.17 3477.21
Total yearly 119636

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 183.34 5683.42
February 261.27 7315.6
March 358.49 11113.1
April 427.13 12813.8
May 467.61 14496
June 482.24 14467.2
July 490.4 15202.5
August 444.86 13790.7
September 370.12 11103.5
October 259.57 8046.82
November 167.96 5038.84
December 124.94 3873
Total yearly 122944

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 199.63 6188.44
February 277.34 7765.59
March 370.43 11483.2
April 431.65 12949.5
May 465.71 14437
June 477.06 14311.9
July 486.72 15088.3
August 446.83 13851.6
September 379.37 11381.2
October 272.29 8441.13
November 180.86 5425.68
December 136.52 4232.03
Total yearly 125556

Chandler Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 214.18 6639.69
February 291.4 8159.09
March 380.12 11783.7
April 433.92 13017.5
May 461.44 14304.6
June 470.09 14102.8
July 481.27 14919.4
August 446.53 13842.5
September 386.41 11592.2
October 283.2 8779.15
November 192.32 5769.68
December 146.9 4553.87
Total yearly 127464

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.79% angle of incidence loss and -1.79% temperature and irradiance loss. This totals to about -14.08%%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels loose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations: