Solar Calculator Canada

Solar Power Calculator for Belledune, New Brunswick, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Belledune
  • GPS Coordinates: 47.864444, -65.921389
  • Elevation: 93 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Belledune: 42o
  • Average yearly irradiance: 1487.36 kWh/m2
  • Average yearly power output: 127030 kWh
Sun Path Belledune

Average yearly irradiance delivered by the Sun in Belledune is 1487.36/kWh/m2 at the optimal panel slope of 42o. After taking all losses into account, you can expect about 127030 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 42o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.69 83.44
February 3.76 105.15
March 4.5 139.46
April 4.84 145.15
May 5.12 158.68
June 5.13 153.82
July 5.4 167.25
August 5.09 157.77
September 4.64 139.33
October 3.37 104.48
November 2.42 72.49
December 1.95 60.34
Total yearly 1487.36

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 256.76 7959.63
February 352.33 9865.35
March 407.18 12622.7
April 418.98 12569.5
May 425.38 13186.7
June 414.69 12440.8
July 429.62 13318.2
August 407.63 12636.6
September 382.54 11476.2
October 288.91 8956.26
November 214.09 6422.72
December 179.84 5574.96
Total yearly 127030

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Belledune solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 174.14 5398.39
February 266.41 7459.41
March 354.1 10977
April 408.97 12269.1
May 449.08 13921.5
June 452.93 13587.9
July 461.94 14320.2
August 411.7 12762.6
September 346.44 10393.3
October 233.95 7252.53
November 152.79 4583.6
December 118.67 3678.69
Total yearly 116604

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 193.53 5999.3
February 287.47 8049.13
March 369.2 11445.3
April 415.82 12474.5
May 449.27 13927.3
June 449.76 13492.9
July 460.18 14265.7
August 415.69 12886.5
September 358.07 10742.1
October 248.08 7690.39
November 167.4 5021.9
December 132.89 4119.62
Total yearly 120115

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 211.18 6546.62
February 306.31 8576.78
March 381.97 11841.1
April 420.42 12612.5
May 447.46 13871.3
June 444.64 13339.2
July 456.36 14147.2
August 417.67 12947.8
September 367.49 11024.8
October 260.49 8075.25
November 180.63 5418.9
December 145.9 4522.75
Total yearly 122924

Belledune Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 227.06 7038.94
February 322.9 9041.08
March 392.36 12163.3
April 422.69 12680.8
May 443.29 13742.1
June 438.08 13142.5
July 451.19 13987
August 417.29 12935.9
September 374.69 11240.5
October 271.16 8405.92
November 192.45 5773.38
December 157.64 4886.8
Total yearly 125038

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.78% angle of incidence loss and -2.39% temperature and irradiance loss. This totals to about -14.59%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

LongviewPennantTantallonMiloAlert BayStewart ValleySpy HillRadium Hot SpringsBinscarthEdenwoldStockholmGeraldYarboCravenNeudorfBethuneGraysonDuchessAbbeyArrowwoodAbernethyRosemaryMcCrearyEyebrowCache CreekMurdochville