Solar Calculator Canada

Solar Power Calculator for Bethune, Saskatchewan, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Bethune
  • GPS Coordinates: 50.7108111, -105.2052667
  • Elevation: 557 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technoloty: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Bethune: 42o
  • Average yearly irradiance: 1521.43 kWh/m2
  • Average yearly power output: 129209 kWh
Sun Path Bethune

Average yearly irradiance delivered by the Sun in Bethune is 1521.43/kWh/m2 at the optimal panel slope of 42o. After taking all losses into account, you can expect about 129209 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 42o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.98 61.45
February 2.73 76.36
March 3.63 112.58
April 5.3 158.92
May 5.69 176.39
June 5.66 169.89
July 6.48 200.95
August 5.84 181.01
September 5.04 151.15
October 3.67 113.89
November 2.26 67.77
December 1.65 51.06
Total yearly 1521.43

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 189.69 5880.5
February 257.88 7220.69
March 326.07 10108.2
April 455.3 13659
May 473.79 14687.6
June 458.52 13755.5
July 518.25 16065.6
August 468.6 14526.5
September 417.17 12515.1
October 317.43 9840.25
November 204.03 6121.02
December 155.78 4829.11
Total yearly 129209

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) fals between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Bethune solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 117.96 3656.86
February 184.59 5168.55
March 275.1 8527.96
April 432.96 12988.9
May 495.46 15359.2
June 498.11 14943.2
July 551.32 17090.9
August 463.46 14367.3
September 365.9 10976.9
October 243.99 7563.65
November 136.08 4082.54
December 92.28 2860.62
Total yearly 117587

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 134.19 4159.85
February 201.84 5651.51
March 288.83 8953.73
April 442.82 13284.7
May 497.52 15423
June 496.68 14900.4
July 551.98 17111.3
August 470.35 14580.9
September 380.86 11425.7
October 261.85 8117.22
November 151.63 4549.05
December 106.53 3302.34
Total yearly 121460

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 149.03 4619.98
February 217.38 6086.73
March 300.61 9318.95
April 450.13 13503.9
May 496.7 15397.7
June 492.68 14780.3
July 549.75 17042.3
August 474.57 14711.8
September 393.36 11800.7
October 277.76 8610.52
November 165.81 4974.32
December 119.61 3707.82
Total yearly 124555

Bethune Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 162.46 5036.34
February 231.19 6473.33
March 310.41 9622.77
April 454.86 13645.7
May 493.29 15291.9
June 485.89 14576.6
July 544.27 16872.3
August 476.15 14760.5
September 403.36 12100.7
October 291.68 9042.06
November 178.57 5357.11
December 131.48 4076.02
Total yearly 126855

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.71% angle of incidence loss and -3.01% temperature and irradiance loss. This totals to about -15.07%%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels loose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations: