Solar Calculator Canada

Solar Power Calculator for Edenwold, Saskatchewan, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Edenwold
  • GPS Coordinates: 50.6337317, -104.2527275
  • Elevation: 661 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Edenwold: 42o
  • Average yearly irradiance: 1553.72 kWh/m2
  • Average yearly power output: 132516 kWh
Sun Path Edenwold

Average yearly irradiance delivered by the Sun in Edenwold is 1553.72/kWh/m2 at the optimal panel slope of 42o. After taking all losses into account, you can expect about 132516 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 42o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.03 62.91
February 2.77 77.58
March 3.58 110.99
April 5.43 162.88
May 5.82 180.34
June 5.78 173.45
July 6.52 202.03
August 5.99 185.8
September 5.21 156.37
October 3.79 117.41
November 2.33 69.92
December 1.74 54.04
Total yearly 1553.72

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 194.84 6039.92
February 262.67 7354.88
March 322.13 9985.91
April 469 14069.9
May 486.85 15092.4
June 470.56 14116.7
July 523.32 16223
August 483.18 14978.6
September 433.36 13000.9
October 328.59 10186.2
November 211.14 6334.31
December 165.6 5133.6
Total yearly 132516

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Edenwold solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 121.64 3770.76
February 190.27 5327.63
March 272.52 8448.04
April 447.61 13428.3
May 508.5 15763.5
June 511.51 15345.3
July 555.77 17228.9
August 476.86 14782.8
September 380.05 11401.6
October 251.74 7803.95
November 141.78 4253.44
December 99.25 3076.77
Total yearly 120631

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 138.14 4282.29
February 207.36 5806
March 285.91 8863.15
April 457.43 13723
May 510.58 15827.9
June 509.62 15288.5
July 556.53 17252.4
August 483.91 15001.1
September 395.55 11866.6
October 270.36 8381.28
November 157.75 4732.47
December 114.13 3537.91
Total yearly 124563

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 153.21 4749.4
February 222.74 6236.6
March 297.37 9218.57
April 464.64 13939.1
May 509.78 15803.3
June 505.21 15156.3
July 553.7 17164.8
August 488.21 15134.5
September 408.49 12254.8
October 286.96 8895.87
November 172.29 5168.61
December 127.78 3961.08
Total yearly 127683

Edenwold Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 166.82 5171.31
February 236.38 6618.52
March 306.89 9513.51
April 469.2 14075.9
May 506.29 15695.1
June 497.88 14936.5
July 547.88 16984.3
August 489.77 15183
September 418.83 12565
October 301.49 9346.18
November 185.36 5560.68
December 140.17 4345.22
Total yearly 129995

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.72% angle of incidence loss and -2.58% temperature and irradiance loss. This totals to about -14.71%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

HughendenGalahadMaymontAmiskSt. BenedictWeekesDonaldaForestburgHeislerChauvinBjorkdaleLairdLougheedEdgertonFerintoshEdbergRosalindStromeNeilburgMarsdenMistatimIrmaBawlfSt. LouisMarcelinMurdochville