Solar Calculator Canada

Solar Power Calculator for Arrowwood, Alberta, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Arrowwood
  • GPS Coordinates: 50.7394444, -113.1483332
  • Elevation: 932 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Arrowwood: 42o
  • Average yearly irradiance: 1580.7 kWh/m2
  • Average yearly power output: 132039 kWh
Sun Path Arrowwood

Average yearly irradiance delivered by the Sun in Arrowwood is 1580.7/kWh/m2 at the optimal panel slope of 42o. After taking all losses into account, you can expect about 132039 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 42o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.07 64.14
February 2.89 80.93
March 4.01 124.3
April 5.21 156.44
May 5.78 179.21
June 5.83 175.01
July 6.68 207
August 6.03 186.93
September 5.16 154.76
October 3.89 120.73
November 2.53 75.96
December 1.78 55.29
Total yearly 1580.7

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 187.81 5822.23
February 257.9 7221.32
March 348.34 10798.7
April 442.17 13265.2
May 476.18 14761.5
June 470.24 14107.1
July 528.42 16381.1
August 480.17 14885.1
September 422.06 12661.8
October 332.45 10305.9
November 225.9 6777.06
December 162.95 5051.41
Total yearly 132039

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Arrowwood solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 119.7 3710.62
February 189.12 5295.4
March 295.07 9147.26
April 423.1 12693
May 495.19 15350.9
June 510.3 15309
July 560.04 17361.2
August 472.68 14653
September 371.19 11135.8
October 255.12 7908.81
November 149.71 4491.32
December 98.04 3039.19
Total yearly 120096

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 135.25 4192.72
February 205.57 5755.87
March 309.45 9592.8
April 432.01 12960.2
May 496.83 15401.8
June 507.7 15231
July 560.07 17362.3
August 480.04 14881.1
September 386.1 11583.1
October 274.01 8494.26
November 167.22 5016.64
December 112.68 3493.04
Total yearly 123965

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 149.44 4632.59
February 220.32 6169
March 321.79 9975.42
April 438.63 13159
May 496.12 15379.6
June 502.78 15083.5
July 557.48 17281.9
August 484.79 15028.6
September 398.53 11956
October 290.83 9015.66
November 183.17 5495.07
December 126.11 3909.4
Total yearly 127086

Arrowwood Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 162.24 5029.44
February 233.36 6534.13
March 332.07 10294.2
April 442.66 13279.7
May 493.43 15296.2
June 495.71 14871.2
July 552.64 17131.8
August 486.78 15090
September 408.45 12253.5
October 305.54 9471.74
November 197.52 5925.49
December 138.29 4287.09
Total yearly 129465

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.69% angle of incidence loss and -4.62% temperature and irradiance loss. This totals to about -16.47%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

HughendenGalahadMaymontAmiskSt. BenedictWeekesDonaldaForestburgHeislerChauvinBjorkdaleLairdLougheedEdgertonFerintoshEdbergRosalindStromeNeilburgMarsdenMistatimIrmaBawlfSt. LouisMarcelinMurdochville