Solar Calculator Canada

Solar Power Calculator for Maisonnette, New Brunswick, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Maisonnette
  • GPS Coordinates: 47.820278, -65.023333
  • Elevation: 1 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Maisonnette: 39o
  • Average yearly irradiance: 1497.65 kWh/m2
  • Average yearly power output: 128251 kWh
Sun Path Maisonnette

Average yearly irradiance delivered by the Sun in Maisonnette is 1497.65/kWh/m2 at the optimal panel slope of 39o. After taking all losses into account, you can expect about 128251 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 39o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.33 72.24
February 2.75 77.12
March 4.15 128.71
April 5.14 154.28
May 5.46 169.4
June 5.54 166.15
July 5.74 178.02
August 5.48 169.76
September 4.84 145.12
October 3.65 113.28
November 2.37 71.16
December 1.69 52.41
Total yearly 1497.65

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 202.08 6264.47
February 234.57 6567.96
March 353.26 10951.2
April 437.09 13112.7
May 465.7 14436.6
June 473.23 14196.8
July 491.77 15244.9
August 468.16 14512.9
September 415.14 12454.3
October 316.05 9797.48
November 205.88 6176.28
December 146.32 4535.86
Total yearly 128251

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Maisonnette solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 143.92 4461.62
February 186.37 5218.34
March 312.36 9683.16
April 424.6 12738.1
May 484.36 15015.3
June 506.95 15208.5
July 519.48 16103.9
August 466.97 14476
September 377.53 11325.8
October 258.5 8013.48
November 151.44 4543.1
December 101.88 3158.19
Total yearly 119946

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 158.83 4923.73
February 199.31 5580.58
March 324.77 10067.8
April 431.62 12948.6
May 484.76 15027.6
June 503.78 15113.4
July 517.88 16054.3
August 471.9 14628.9
September 389.9 11696.9
October 274.24 8501.46
November 165.48 4964.28
December 113.18 3508.49
Total yearly 123016

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 172.28 5340.7
February 210.73 5900.48
March 335.14 10389.4
April 436.34 13090.1
May 482.94 14971
June 498.56 14956.9
July 514.04 15935.4
August 474.51 14709.9
September 399.89 11996.6
October 288.04 8929.09
November 178.13 5343.77
December 123.43 3826.29
Total yearly 125390

Maisonnette Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 184.27 5712.23
February 220.64 6177.92
March 343.48 10647.9
April 438.73 13161.8
May 478.64 14837.8
June 491.46 14743.9
July 508.41 15760.8
August 474.59 14712.4
September 407.49 12224.8
October 299.87 9295.9
November 189.36 5680.91
December 132.61 4111.02
Total yearly 127067

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.73% angle of incidence loss and -2.18% temperature and irradiance loss. This totals to about -14.36%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

LongviewPennantTantallonMiloAlert BayStewart ValleySpy HillRadium Hot SpringsBinscarthEdenwoldStockholmGeraldYarboCravenNeudorfBethuneGraysonDuchessAbbeyArrowwoodAbernethyRosemaryMcCrearyEyebrowCache CreekMurdochville