Solar Calculator Canada

Solar Power Calculator for Landrienne, Quebec, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Landrienne
  • GPS Coordinates: 48.55, -77.95
  • Elevation: 314 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Landrienne: 40o
  • Average yearly irradiance: 1425.08 kWh/m2
  • Average yearly power output: 121417 kWh
Sun Path Landrienne

Average yearly irradiance delivered by the Sun in Landrienne is 1425.08/kWh/m2 at the optimal panel slope of 40o. After taking all losses into account, you can expect about 121417 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 40o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.36 73.28
February 3.44 96.37
March 4.48 138.93
April 4.68 140.29
May 5.39 167.16
June 5.55 166.55
July 5.38 166.81
August 5.06 156.77
September 4.24 127.23
October 2.77 85.97
November 1.87 56.06
December 1.6 49.67
Total yearly 1425.08

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 228.29 7076.98
February 327.32 9164.96
March 407.61 12635.9
April 403.58 12107.3
May 445.3 13804.4
June 445.96 13378.8
July 429.21 13305.4
August 407.1 12620
September 348.43 10452.8
October 235.32 7295.03
November 164.37 4930.97
December 149.83 4644.71
Total yearly 121417

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Landrienne solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 157.21 4873.5
February 251.19 7033.24
March 353.62 10962.3
April 393.83 11814.8
May 465.85 14441.3
June 481.65 14449.4
July 457.29 14176.1
August 408.11 12651.5
September 317.54 9526.21
October 195.57 6062.79
November 120.87 3626.2
December 101.14 3135.26
Total yearly 112753

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 174.61 5413.01
February 270.58 7576.23
March 369.19 11445
April 400.09 12002.6
May 466.57 14463.6
June 478.79 14363.8
July 455.83 14130.8
August 412.3 12781.4
September 327.68 9830.27
October 206.28 6394.62
November 131.69 3950.68
December 113.02 3503.73
Total yearly 115856

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 190.42 5902.98
February 287.9 8061.08
March 382.4 11854.3
April 404.21 12126.3
May 464.79 14408.4
June 474.36 14230.8
July 452.7 14033.8
August 414.24 12841.5
September 335.85 10075.5
October 215.62 6684.26
November 141.46 4243.84
December 123.83 3838.76
Total yearly 118302

Landrienne Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 204.6 6342.48
February 303.1 8486.85
March 393.2 12189.2
April 406.2 12186
May 460.66 14280.5
June 467.21 14016.2
July 447.04 13858.1
August 414.03 12834.9
September 342.07 10262.1
October 223.57 6930.76
November 150.15 4504.63
December 133.54 4139.81
Total yearly 120032

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.84% angle of incidence loss and -2.56% temperature and irradiance loss. This totals to about -14.8%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.