Solar Power Calculator for Marcelin, Saskatchewan, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Marcelin
  • GPS Coordinates: 52.9260139, -106.790675
  • Elevation: 522 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Marcelin: 44o
  • Average yearly irradiance: 1448.72 kWh/m2
  • Average yearly power output: 123133 kWh
Sun Path Marcelin

Average yearly irradiance delivered by the Sun in Marcelin is 1448.72/kWh/m2 at the optimal panel slope of 44o. After taking all losses into account, you can expect about 123133 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 44o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.61 49.78
February 2.46 68.96
March 3.57 110.58
April 5.12 153.72
May 5.97 185
June 5.48 164.33
July 6.14 190.31
August 5.67 175.86
September 4.76 142.72
October 3.47 107.72
November 1.77 53.2
December 1.5 46.54
Total yearly 1448.72

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 153.68 4764.18
February 232.14 6499.82
March 321.31 9960.68
April 441.78 13253.3
May 497.65 15427.2
June 443.25 13297.6
July 491.57 15238.8
August 458.65 14218.2
September 395.24 11857.2
October 301.47 9345.48
November 161.08 4832.29
December 143.19 4438.74
Total yearly 123133

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Marcelin solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 90.65 2810.02
February 160.37 4490.48
March 263.39 8165.2
April 416.06 12481.9
May 513.82 15928.3
June 478.99 14369.8
July 520.68 16141
August 448.71 13909.9
September 341.25 10237.4
October 224.57 6961.53
November 102.68 3080.47
December 79.27 2457.27
Total yearly 111033

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 104.41 3236.64
February 176.84 4951.41
March 278.4 8630.29
April 426.42 12792.7
May 517.54 16043.6
June 478.16 14344.9
July 521.71 16173
August 456.48 14150.8
September 356.23 10686.9
October 242.61 7521.01
November 115.53 3465.98
December 93.07 2885.02
Total yearly 114882

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 117.05 3628.46
February 191.71 5367.96
March 291.42 9034.15
April 434.3 13028.9
May 518.32 16068
June 474.97 14249.1
July 520.21 16126.4
August 461.66 14311.3
September 368.89 11066.8
October 258.79 8022.51
November 127.29 3818.74
December 105.8 3279.78
Total yearly 118002

Marcelin Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 128.53 3984.37
February 204.98 5739.52
March 302.45 9376.1
April 439.67 13190.1
May 516.21 16002.5
June 469.6 14088.1
July 516.27 16004.4
August 464.23 14391
September 379.19 11375.8
October 273.05 8464.53
November 137.92 4137.61
December 117.42 3640.01
Total yearly 120394

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.75% angle of incidence loss and -2.89% temperature and irradiance loss. This totals to about -15.01%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations: