Solar Calculator Canada

Solar Power Calculator for Bon Accord, Alberta, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Bon Accord
  • GPS Coordinates: 53.8369444, -113.4122222
  • Elevation: 699 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Bon Accord: 44o
  • Average yearly irradiance: 1421.96 kWh/m2
  • Average yearly power output: 120401 kWh
Sun Path Bon Accord

Average yearly irradiance delivered by the Sun in Bon Accord is 1421.96/kWh/m2 at the optimal panel slope of 44o. After taking all losses into account, you can expect about 120401 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 44o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.45 45.09
February 2.44 68.23
March 3.44 106.58
April 5.06 151.89
May 5.9 182.93
June 5.74 172.14
July 6.13 190.06
August 5.62 174.1
September 4.53 135.91
October 3.24 100.37
November 1.86 55.66
December 1.26 38.99
Total yearly 1421.96

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 136.69 4237.37
February 225.17 6304.9
March 306.96 9515.7
April 435.27 13058
May 490.99 15220.8
June 466.59 13997.7
July 492.06 15254
August 454.77 14097.8
September 376.76 11302.8
October 280.21 8686.43
November 168.23 5046.9
December 118.67 3678.92
Total yearly 120401

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Bon Accord solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 80.6 2498.62
February 154.46 4324.76
March 252.26 7819.95
April 408.03 12241
May 504.24 15631.5
June 499.83 14995
July 516.38 16007.8
August 443.4 13745.5
September 325.6 9768.08
October 209.11 6482.35
November 105.58 3167.3
December 66.42 2058.92
Total yearly 108741

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 92.95 2881.39
February 170.64 4778.03
March 266.4 8258.39
April 418.5 12555.1
May 507.39 15729
June 498.96 14968.7
July 517.63 16046.4
August 451.1 13984
September 339.73 10191.9
October 225.78 6999.33
November 119.4 3581.94
December 77.81 2412.02
Total yearly 112386

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 104.29 3232.93
February 185.3 5188.4
March 278.69 8639.39
April 426.65 12799.5
May 508.01 15748.4
June 495.71 14871.4
July 516.32 16006
August 456.48 14151
September 351.67 10550
October 240.74 7463.09
November 132.06 3961.94
December 88.29 2737.01
Total yearly 115349

Bon Accord Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 114.59 3552.32
February 198.4 5555.13
March 289.11 8962.29
April 432.32 12969.5
May 506.3 15695.3
June 490.22 14706.5
July 512.83 15897.8
August 459.31 14238.7
September 361.38 10841.3
October 253.94 7872.11
November 143.54 4306.07
December 97.84 3033.09
Total yearly 117630

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.76% angle of incidence loss and -3.25% temperature and irradiance loss. This totals to about -15.33%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

Rivi�re-VerteLac BakerSaint-IsidoreThornloePaquetvilleN�d�lecLe GouletNigadooBertrandSaint-L�olinSainte-Marie-Saint-Rapha�lPetit-RocherBas-CaraquetGrande-AnseMaisonnettePointe-VerteBelleduneBalmoralAtholvilleCharloEel River CrossingLandrienneNorth PortalCouttsMidwayMurdochville