Solar Calculator Canada

Solar Power Calculator for Warfield, British Columbia, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Warfield
  • GPS Coordinates: 49.094167, -117.749167
  • Elevation: 613 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Warfield: 36o
  • Average yearly irradiance: 1418.63 kWh/m2
  • Average yearly power output: 115209 kWh
Sun Path Warfield

Average yearly irradiance delivered by the Sun in Warfield is 1418.63/kWh/m2 at the optimal panel slope of 36o. After taking all losses into account, you can expect about 115209 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 36o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.29 40.04
February 2.48 69.43
March 3.36 104.31
April 4.75 142.46
May 5.57 172.6
June 5.27 158.03
July 6.77 209.72
August 6.25 193.6
September 4.96 148.82
October 3.06 94.78
November 1.59 47.79
December 1.2 37.05
Total yearly 1418.63

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 111.77 3464.97
February 215.34 6029.44
March 289.1 8962.03
April 399.06 11971.8
May 449.79 13943.6
June 418.3 12549
July 521.68 16172.2
August 484.28 15012.6
September 395.6 11868
October 254.66 7894.59
November 136.77 4103.05
December 104.45 3237.81
Total yearly 115209

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Warfield solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 86.63 2685.58
February 177.13 4959.7
March 258.23 8005
April 386.55 11596.4
May 458.36 14209.2
June 440.43 13213
July 540.73 16762.6
August 474.07 14696.2
September 357.9 10737.1
October 215.59 6683.16
November 106.18 3185.45
December 77.22 2393.88
Total yearly 109127

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 94.29 2922.86
February 188.87 5288.47
March 267.75 8300.37
April 392.19 11765.8
May 458.89 14225.5
June 437.06 13111.8
July 539.81 16734
August 480.02 14880.7
September 370.29 11108.8
October 227.81 7061.96
November 115.17 3455.2
December 85.27 2643.45
Total yearly 111499

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 101.1 3134.16
February 199.2 5577.51
March 275.69 8546.46
April 395.81 11874.4
May 457.22 14173.9
June 432.39 12971.7
July 535.82 16610.4
August 483.33 14983.1
September 380.41 11412.2
October 238.44 7391.74
November 123.19 3695.72
December 92.49 2867.04
Total yearly 113238

Warfield Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 107.09 3319.84
February 208.11 5826.96
March 282.02 8742.73
April 397.38 11921.5
May 453.16 14047.9
June 425.28 12758.5
July 529.04 16400.2
August 483.98 15003.3
September 388.23 11646.8
October 247.49 7672.32
November 130.24 3907.21
December 98.88 3065.16
Total yearly 114312

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.86% angle of incidence loss and -7.11% temperature and irradiance loss. This totals to about -18.79%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

BeloeilSainte-JulieThursoActon ValeMirabelRichmondBlainvilleVarennesTerrebonneRepentignySainte-Anne-des-PlainesDanvilleL'AssomptionSaint-Lin-LaurentidesContrecoeurKingsey FallsPr�vostLavaltrieSaint-OursSaint-SauveurDisraeliSainte-Ad�leWarwickSainte-Agathe-des-MontsDieppeMurdochville