Solar Calculator Canada

Solar Power Calculator for Sainte-Brigitte-de-Laval, Quebec, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Sainte-Brigitte-de-Laval
  • GPS Coordinates: 47, -71.2
  • Elevation: 295 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Sainte-Brigitte-de-Laval: 39o
  • Average yearly irradiance: 1452.28 kWh/m2
  • Average yearly power output: 123073 kWh
Sun Path Sainte-Brigitte-de-Laval

Average yearly irradiance delivered by the Sun in Sainte-Brigitte-de-Laval is 1452.28/kWh/m2 at the optimal panel slope of 39o. After taking all losses into account, you can expect about 123073 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 39o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.62 81.3
February 3.43 96.17
March 4.49 139.08
April 4.79 143.7
May 5.25 162.72
June 5.24 157.14
July 5.48 169.84
August 5.12 158.75
September 4.25 127.59
October 3.03 93.94
November 2.16 64.7
December 1.85 57.34
Total yearly 1452.28

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 248.49 7703.23
February 321.56 9003.76
March 404.47 12538.7
April 410.22 12306.7
May 432.16 13397.1
June 419.81 12594.2
July 434.49 13469.1
August 409.41 12691.6
September 347.22 10416.7
October 257.57 7984.77
November 189.68 5690.35
December 170.21 5276.53
Total yearly 123073

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Sainte-Brigitte-de-Laval solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 177.57 5504.59
February 253.52 7098.69
March 355.05 11006.5
April 399.89 11996.6
May 452.12 14015.7
June 452.41 13572.2
July 460.25 14267.6
August 411.2 12747.2
September 319.24 9577.34
October 216.05 6697.42
November 142.7 4281.04
December 119.32 3698.9
Total yearly 114464

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 195.37 6056.35
February 271.04 7589.14
March 369.42 11452.2
April 405.91 12177.2
May 452.23 14019.2
June 449.51 13485.2
July 459.11 14232.3
August 414.82 12859.6
September 328.83 9864.81
October 227.44 7050.58
November 154.72 4641.58
December 132.19 4097.81
Total yearly 117526

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 211.39 6553.03
February 286.54 8023.08
March 381.49 11826.1
April 409.72 12291.5
May 450.14 13954.2
June 445.03 13350.8
July 455.53 14121.5
August 416.25 12903.6
September 336.44 10093.3
October 237.31 7356.62
November 165.48 4964.36
December 143.82 4458.41
Total yearly 119896

Sainte-Brigitte-de-Laval Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 225.64 6994.81
February 300 8400.03
March 391.21 12127.4
April 411.29 12338.8
May 445.58 13812.9
June 437.92 13137.7
July 449.56 13936.3
August 415.45 12879
September 342.07 10262.2
October 245.64 7614.98
November 174.97 5249.11
December 154.21 4780.65
Total yearly 121534

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.73% angle of incidence loss and -3.2% temperature and irradiance loss. This totals to about -15.26%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

Saint-PhilippeSaint-AugustinSaint-Adolphe-de-DudswellPointe-au-Ch�neSainte-ScholastiqueSainte-MoniqueSaint-Louis-de-TerrebonneSaint-JanvierSaint-Pierre-de-WakefieldSainte-Jeanne-d'ArcSaint-Simon-de-BagotLakefieldLadysmithLost RiverSaint-JosephSaints-MartyrsLesageDavidsonShawbridgeMontfortSaint-MajoriqueWeirSainte-VictoireSaint-David-d'YamaskaVimy-RidgeMurdochville