Solar Calculator Canada

Solar Power Calculator for Davidson, Quebec, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Davidson
  • GPS Coordinates: 45.869444, -76.766389
  • Elevation: 118 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Davidson: 39o
  • Average yearly irradiance: 1548.33 kWh/m2
  • Average yearly power output: 129917 kWh
Sun Path Davidson

Average yearly irradiance delivered by the Sun in Davidson is 1548.33/kWh/m2 at the optimal panel slope of 39o. After taking all losses into account, you can expect about 129917 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 39o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.73 84.48
February 3.53 98.72
March 4.7 145.71
April 5.03 150.95
May 5.55 172.2
June 5.63 168.98
July 5.84 181.16
August 5.55 172.06
September 4.63 139.03
October 3.27 101.23
November 2.51 75.45
December 1.88 58.35
Total yearly 1548.33

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 256.43 7949.31
February 327.53 9170.83
March 420.95 13049.5
April 426.93 12807.9
May 451.52 13997.1
June 447.41 13422.3
July 458.84 14224.1
August 440.07 13642.3
September 375.07 11252.2
October 274.48 8508.89
November 219.44 6583.27
December 171.28 5309.62
Total yearly 129917

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Davidson solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 184.12 5707.77
February 260.62 7297.43
March 371.8 11525.8
April 418.63 12558.9
May 475.13 14729.2
June 484.8 14544.1
July 490.96 15219.7
August 443.8 13757.8
September 346.59 10397.8
October 231.36 7172.05
November 164.76 4942.8
December 121.46 3765.24
Total yearly 121619

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 202.79 6286.46
February 278.59 7800.48
March 386.71 11988
April 424.67 12740.2
May 474.54 14710.8
June 481.37 14441.2
July 488.86 15154.8
August 447.41 13869.6
September 356.61 10698.4
October 243.49 7548.15
November 178.99 5369.64
December 134.21 4160.56
Total yearly 124768

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 219.66 6809.45
February 294.52 8246.44
March 399.2 12375.1
April 428.43 12852.9
May 471.55 14618.2
June 475.36 14260.7
July 484.08 15006.5
August 448.67 13908.7
September 364.53 10935.8
October 254.03 7874.89
November 191.8 5754.1
December 145.77 4518.81
Total yearly 127162

Davidson Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 234.71 7275.95
February 308.37 8634.37
March 409.23 12686.1
April 429.89 12896.6
May 466.21 14452.6
June 467.06 14011.8
July 476.91 14784.4
August 447.58 13874.9
September 370.31 11109.2
October 262.94 8151.23
November 203.17 6095.01
December 156.11 4839.32
Total yearly 128811

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.81% angle of incidence loss and -4.08% temperature and irradiance loss. This totals to about -16.09%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

WarfieldBrackenForgetHazenmoreMcTaggartHewardFairlightOsageBaronsCarmichaelGarsonShamrockKendalWelwynBelle PlaineRush LakeGrand CouleeErnfoldMortlachSuccessTuxfordMarquisDisleyKeelerDubucMurdochville