Solar Power Calculator for Shamrock, Saskatchewan, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Shamrock
  • GPS Coordinates: 50.1607222, -106.6249528
  • Elevation: 724 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Shamrock: 42o
  • Average yearly irradiance: 1573.87 kWh/m2
  • Average yearly power output: 133230 kWh
Sun Path Shamrock

Average yearly irradiance delivered by the Sun in Shamrock is 1573.87/kWh/m2 at the optimal panel slope of 42o. After taking all losses into account, you can expect about 133230 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 42o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.06 63.79
February 2.82 78.85
March 3.92 121.67
April 5.35 160.38
May 5.66 175.4
June 5.77 173.19
July 6.71 207.93
August 6.11 189.29
September 5.13 153.82
October 3.97 123.17
November 2.38 71.28
December 1.78 55.11
Total yearly 1573.87

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 193.92 6011.45
February 261.42 7319.85
March 348.72 10810.5
April 459.22 13776.6
May 471.87 14628.1
June 467.9 14036.9
July 535.07 16587
August 489.37 15170.4
September 422.83 12684.9
October 342.95 10631.4
November 213.45 6403.38
December 166.76 5169.66
Total yearly 133230

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Shamrock solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 123 3812.95
February 190.33 5329.18
March 296.39 9188.02
April 437 13110
May 490.95 15219.5
June 507.4 15222
July 568.21 17614.6
August 482.9 14969.8
September 372.11 11163.4
October 264.22 8190.73
November 144.04 4321.12
December 100.58 3117.9
Total yearly 121259

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 139.49 4324.27
February 207.64 5813.79
March 310.91 9638.3
April 446.43 13393
May 492.54 15268.7
June 505.21 15156.3
July 568.15 17612.7
August 490.17 15195.3
September 387.02 11610.6
October 283.64 8792.76
November 160.16 4804.87
December 115.82 3590.47
Total yearly 125201

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 154.57 4791.58
February 223.21 6249.76
March 323.37 10024.4
April 453.33 13599.9
May 491.4 15233.3
June 500.61 15018.3
July 565.61 17534
August 494.61 15332.9
September 399.44 11983.1
October 300.94 9329.15
November 174.86 5245.77
December 129.79 4023.51
Total yearly 128366

Shamrock Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 168.19 5213.91
February 237.01 6636.18
March 333.72 10345.2
April 457.66 13729.7
May 487.72 15119.3
June 493.1 14792.8
July 559.66 17349.6
August 496.27 15384.5
September 409.32 12279.7
October 316.07 9798.29
November 188.08 5642.48
December 142.46 4416.13
Total yearly 130708

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.7% angle of incidence loss and -3.34% temperature and irradiance loss. This totals to about -15.35%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

BeloeilSainte-JulieThursoActon ValeMirabelRichmondBlainvilleVarennesTerrebonneRepentignySainte-Anne-des-PlainesDanvilleL'AssomptionSaint-Lin-LaurentidesContrecoeurKingsey FallsPr�vostLavaltrieSaint-OursSaint-SauveurDisraeliSainte-Ad�leWarwickSainte-Agathe-des-MontsDieppeMurdochville