Solar Calculator Canada

Solar Power Calculator for Kendal, Saskatchewan, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Kendal
  • GPS Coordinates: 50.2548806, -103.6158889
  • Elevation: 660 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Kendal: 42o
  • Average yearly irradiance: 1562.19 kWh/m2
  • Average yearly power output: 133143 kWh
Sun Path Kendal

Average yearly irradiance delivered by the Sun in Kendal is 1562.19/kWh/m2 at the optimal panel slope of 42o. After taking all losses into account, you can expect about 133143 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 42o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.05 63.61
February 2.88 80.76
March 3.48 107.92
April 5.43 162.91
May 5.91 183.14
June 5.84 175.19
July 6.59 204.41
August 5.94 184.07
September 5.3 158.94
October 3.77 116.96
November 2.37 71.08
December 1.72 53.2
Total yearly 1562.19

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 196.9 6104.01
February 273.57 7659.93
March 312.03 9672.96
April 468.68 14060.5
May 494.47 15328.6
June 475.02 14250.5
July 529.25 16406.7
August 478.36 14829.1
September 440.33 13210
October 326.99 10136.6
November 214.75 6442.37
December 162.63 5041.5
Total yearly 133143

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Kendal solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 123.61 3832.04
February 195.43 5471.96
March 263.19 8158.87
April 447.86 13435.7
May 517.34 16037.4
June 516.76 15502.9
July 561.9 17418.9
August 473.27 14671.5
September 387.13 11613.9
October 252.64 7831.72
November 145.29 4358.62
December 98.2 3044.3
Total yearly 121378

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 140.21 4346.64
February 213.82 5986.93
March 276.38 8567.65
April 457.5 13725.1
May 519.18 16094.7
June 514.62 15438.5
July 562.65 17442.1
August 479.93 14877.8
September 402.8 12084
October 270.87 8396.9
November 161.38 4841.3
December 112.7 3493.84
Total yearly 125295

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 155.37 4816.54
February 230.38 6450.53
March 287.68 8918.03
April 464.53 13935.9
May 518.26 16066
June 510.13 15303.8
July 559.76 17352.6
August 483.9 15001
September 415.86 12476
October 287.09 8899.89
November 176.01 5280.43
December 126 3906.03
Total yearly 128407

Kendal Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 169.06 5240.97
February 245.07 6861.97
March 297.07 9209.25
April 468.92 14067.6
May 514.53 15950.4
June 502.61 15078.4
July 553.84 17169.1
August 485.19 15040.9
September 426.29 12788.7
October 301.26 9339.15
November 189.16 5674.86
December 138.06 4279.91
Total yearly 130701

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.7% angle of incidence loss and -2.67% temperature and irradiance loss. This totals to about -14.77%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations: