Solar Calculator Canada

Solar Power Calculator for L'Ancienne-Lorette, Quebec, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: L'Ancienne-Lorette
  • GPS Coordinates: 46.79873, -71.36255
  • Elevation: 57 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for L'Ancienne-Lorette: 40o
  • Average yearly irradiance: 1492.56 kWh/m2
  • Average yearly power output: 126096 kWh
Sun Path L'Ancienne-Lorette

Average yearly irradiance delivered by the Sun in L'Ancienne-Lorette is 1492.56/kWh/m2 at the optimal panel slope of 40o. After taking all losses into account, you can expect about 126096 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 40o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.74 84.91
February 3.37 94.46
March 4.39 136.11
April 4.84 145.1
May 5.3 164.44
June 5.36 160.67
July 5.69 176.46
August 5.3 164.17
September 4.47 134.16
October 3.25 100.86
November 2.39 71.61
December 1.92 59.62
Total yearly 1492.56

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 259 8029.12
February 314.52 8806.6
March 394.55 12231.2
April 414.73 12442
May 435.83 13510.8
June 427.94 12838.1
July 450.21 13956.5
August 421.75 13074.4
September 362.93 10887.8
October 275.95 8554.35
November 209.64 6289.33
December 176.64 5475.91
Total yearly 126096

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

L'Ancienne-Lorette solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 179.51 5564.67
February 246.66 6906.61
March 347.5 10772.6
April 406.39 12191.8
May 458.04 14199.3
June 464.18 13925.3
July 481.22 14917.9
August 424.87 13171
September 333.45 10003.5
October 228.16 7072.97
November 154.1 4623.13
December 119.36 3700.25
Total yearly 117049

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 199.1 6172.23
February 264.24 7398.67
March 361.52 11207.2
April 412.46 12373.8
May 457.96 14196.9
June 460.86 13825.8
July 479.66 14869.4
August 428.68 13289.2
September 343.6 10308
October 241.07 7473.04
November 168.04 5041.18
December 133.37 4134.38
Total yearly 120290

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 216.91 6724.35
February 279.85 7835.7
March 373.29 11571.8
April 416.32 12489.6
May 455.66 14125.3
June 455.91 13677.3
July 475.56 14742.4
August 430.25 13337.9
September 351.69 10550.6
October 252.35 7822.94
November 180.6 5418.01
December 146.14 4530.49
Total yearly 122826

L'Ancienne-Lorette Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 232.89 7219.63
February 293.46 8216.78
March 382.76 11865.5
April 418.07 12542.1
May 451.02 13981.5
June 448.43 13452.8
July 469.05 14540.7
August 429.6 13317.5
September 357.68 10730.5
October 261.98 8121.52
November 191.76 5752.76
December 157.66 4887.36
Total yearly 124629

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.8% angle of incidence loss and -3.43% temperature and irradiance loss. This totals to about -15.52%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

BoisbriandRosem�reSainte-Th�r�seSaint-AmableLorraineBois-des-FilionBrownsburg-ChathamCharlemagneSaint-ColombanMascoucheL'�piphanieBarkmereSaint-Joseph-de-SorelCap-Sant�NeuvilleSaint-Augustin-de-DesmauresSainte-Catherine-de-la-Jacques-CartierFossambault-sur-le-LacLac-SergentShannonLac-Saint-JosephLac-DelageSainte-Brigitte-de-LavalBeaupr�ColwoodMurdochville