The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Ladysmith
  • GPS Coordinates: 45.761667, -76.388889
  • Elevation: 208 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Ladysmith: 39o
  • Average yearly irradiance: 1565.29 kWh/m2
  • Average yearly power output: 131760 kWh
Sun Path Ladysmith

Average yearly irradiance delivered by the Sun in Ladysmith is 1565.29/kWh/m2 at the optimal panel slope of 39o. After taking all losses into account, you can expect about 131760 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 39o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.91 90.15
February 3.85 107.78
March 4.89 151.55
April 5.05 151.63
May 5.5 170.47
June 5.48 164.28
July 5.73 177.73
August 5.49 170.21
September 4.68 140.35
October 3.29 102.02
November 2.61 78.19
December 1.97 60.92
Total yearly 1565.29

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 273.98 8493.33
February 357.83 10019.2
March 436.99 13546.7
April 428.29 12848.7
May 447.97 13887
June 435.97 13079
July 451.33 13991.1
August 436.36 13527.3
September 379.3 11378.9
October 277.22 8593.94
November 227.69 6830.58
December 179.5 5564.55
Total yearly 131760

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Ladysmith solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 195.05 6046.43
February 282.04 7897.25
March 385.01 11935.4
April 421.04 12631.1
May 473.09 14665.7
June 475.38 14261.4
July 485.55 15052.2
August 441.73 13693.5
September 350.25 10507.7
October 232.9 7219.91
November 170.42 5112.53
December 127.14 3941.41
Total yearly 122965

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 215.09 6667.91
February 302.05 8457.37
March 400.63 12419.6
April 426.98 12809.5
May 472.38 14643.6
June 471.69 14150.7
July 483.18 14978.5
August 445.05 13796.7
September 360.42 10812.5
October 245.2 7601.27
November 185.14 5554.23
December 140.39 4352.03
Total yearly 126244

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 233.22 7229.71
February 319.81 8954.65
March 413.73 12825.6
April 430.61 12918.4
May 469.3 14548.2
June 465.47 13964.1
July 478.16 14822.9
August 446.06 13827.7
September 368.43 11053
October 255.89 7932.61
November 198.38 5951.41
December 152.37 4723.55
Total yearly 128752

Ladysmith Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 249.39 7731.04
February 335.29 9388.1
March 424.27 13152.4
April 431.93 12957.8
May 463.88 14380.4
June 457.04 13711.1
July 470.8 14594.7
August 444.73 13786.8
September 374.29 11228.6
October 264.93 8212.89
November 210.1 6303.12
December 163.08 5055.49
Total yearly 130502

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.8% angle of incidence loss and -3.78% temperature and irradiance loss. This totals to about -15.82%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

WarfieldBrackenForgetHazenmoreMcTaggartHewardFairlightOsageBaronsCarmichaelGarsonShamrockKendalWelwynBelle PlaineRush LakeGrand CouleeErnfoldMortlachSuccessTuxfordMarquisDisleyKeelerDubucMurdochville