Solar Calculator Canada

Solar Power Calculator for Launay, Quebec, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Launay
  • GPS Coordinates: 48.65, -78.5333333
  • Elevation: 327 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Launay: 41o
  • Average yearly irradiance: 1447.73 kWh/m2
  • Average yearly power output: 123746 kWh
Sun Path Launay

Average yearly irradiance delivered by the Sun in Launay is 1447.73/kWh/m2 at the optimal panel slope of 41o. After taking all losses into account, you can expect about 123746 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 41o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.66 82.52
February 3.69 103.36
March 4.69 145.5
April 4.79 143.71
May 5.32 164.86
June 5.48 164.31
July 5.3 164.35
August 5 154.96
September 4.17 125.24
October 2.81 86.96
November 1.93 57.86
December 1.75 54.1
Total yearly 1447.73

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 258 7998.11
February 351.66 9846.41
March 427.1 13240.2
April 413.31 12399.2
May 439.3 13618.2
June 440.21 13206.3
July 422.75 13105.3
August 402.06 12463.8
September 342.66 10279.7
October 238.26 7386.01
November 170.54 5116.06
December 164.1 5087
Total yearly 123746

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Launay solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 173.05 5364.53
February 267.18 7480.96
March 368.64 11427.8
April 403.21 12096.4
May 461.55 14308.1
June 478.01 14340.4
July 452.92 14040.7
August 404.7 12545.6
September 312.2 9365.96
October 196.99 6106.68
November 123.74 3712.15
December 109.01 3379.32
Total yearly 114168

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 193.22 5989.68
February 288.13 8067.6
March 385.13 11939
April 409.82 12294.5
May 462.2 14328.3
June 475.05 14251.6
July 451.33 13991.1
August 408.71 12670
September 322.15 9664.45
October 207.87 6444.02
November 135.05 4051.6
December 122.07 3784.12
Total yearly 117476

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 211.57 6558.73
February 306.86 8592.06
March 399.15 12373.6
April 414.23 12426.8
May 460.45 14273.9
June 470.44 14113.2
July 447.96 13886.8
August 410.56 12727.3
September 330.18 9905.49
October 217.37 6738.56
November 145.29 4358.64
December 133.96 4152.71
Total yearly 120108

Launay Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 228.08 7070.45
February 323.33 9053.27
March 410.66 12730.6
April 416.45 12493.4
May 456.34 14146.4
June 463.45 13903.6
July 442.54 13718.7
August 410.33 12720.4
September 336.27 10088.1
October 225.46 6989.37
November 154.41 4632.18
December 144.66 4484.38
Total yearly 122031

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.83% angle of incidence loss and -2.26% temperature and irradiance loss. This totals to about -14.52%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

BeloeilSainte-JulieThursoActon ValeMirabelRichmondBlainvilleVarennesTerrebonneRepentignySainte-Anne-des-PlainesDanvilleL'AssomptionSaint-Lin-LaurentidesContrecoeurKingsey FallsPr�vostLavaltrieSaint-OursSaint-SauveurDisraeliSainte-Ad�leWarwickSainte-Agathe-des-MontsDieppeMurdochville