Solar Calculator Canada

Solar Power Calculator for Montfort, Quebec, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Montfort
  • GPS Coordinates: 45.8858333, -74.3408333
  • Elevation: 403 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Montfort: 39o
  • Average yearly irradiance: 1536.06 kWh/m2
  • Average yearly power output: 129650 kWh
Sun Path Montfort

Average yearly irradiance delivered by the Sun in Montfort is 1536.06/kWh/m2 at the optimal panel slope of 39o. After taking all losses into account, you can expect about 129650 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 39o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.75 85.28
February 3.72 104.21
March 4.73 146.53
April 4.99 149.75
May 5.41 167.58
June 5.34 160.34
July 5.72 177.2
August 5.46 169.32
September 4.67 140.15
October 3.22 99.87
November 2.55 76.42
December 1.92 59.4
Total yearly 1536.06

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 258.45 8011.9
February 346.61 9705.03
March 423.63 13132.6
April 425.28 12758.5
May 442.16 13707
June 427.15 12814.4
July 452.82 14037.5
August 436.53 13532.3
September 379.79 11393.7
October 272.37 8443.49
November 223.22 6696.74
December 174.73 5416.53
Total yearly 129650

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Montfort solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 187.07 5799.2
February 274.88 7696.56
March 374.91 11622.3
April 417.56 12526.7
May 466.75 14469.1
June 465.39 13961.8
July 486.31 15075.7
August 440.55 13656.9
September 349.91 10497.2
October 228.97 7097.94
November 169.1 5072.97
December 125.01 3875.22
Total yearly 121352

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 205.39 6367.15
February 294.06 8233.58
March 389.87 12086
April 423.59 12707.8
May 465.94 14444.2
June 461.47 13844.1
July 483.63 14992.6
August 444.1 13767.2
September 360.22 10806.7
October 241.07 7473.27
November 183.26 5497.74
December 137.71 4268.87
Total yearly 124489

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 221.87 6877.96
February 311.04 8709.01
March 402.38 12473.8
April 427.32 12819.7
May 462.81 14347
June 455.29 13658.6
July 478.49 14833.2
August 445.31 13804.6
September 368.37 11051.2
October 251.57 7798.79
November 195.92 5877.51
December 149.15 4623.5
Total yearly 126875

Montfort Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 236.5 7331.56
February 325.79 9122.22
March 412.4 12784.5
April 428.73 12862
May 457.37 14178.6
June 446.94 13408.2
July 470.99 14600.7
August 444.17 13769.2
September 374.34 11230.1
October 260.44 8073.67
November 207.07 6212.06
December 159.33 4939.08
Total yearly 128512

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.78% angle of incidence loss and -3.53% temperature and irradiance loss. This totals to about -15.6%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

WarfieldBrackenForgetHazenmoreMcTaggartHewardFairlightOsageBaronsCarmichaelGarsonShamrockKendalWelwynBelle PlaineRush LakeGrand CouleeErnfoldMortlachSuccessTuxfordMarquisDisleyKeelerDubucMurdochville