Solar Calculator Canada

Solar Power Calculator for Saint-Majorique, Quebec, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Saint-Majorique
  • GPS Coordinates: 45.9316667, -72.5822222
  • Elevation: 72 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technoloty: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Saint-Majorique: 40o
  • Average yearly irradiance: 1545.54 kWh/m2
  • Average yearly power output: 130316 kWh
Sun Path Saint-Majorique

Average yearly irradiance delivered by the Sun in Saint-Majorique is 1545.54/kWh/m2 at the optimal panel slope of 40o. After taking all losses into account, you can expect about 130316 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 40o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.93 90.71
February 3.47 97.27
March 4.43 137.45
April 4.94 148.09
May 5.45 168.81
June 5.47 164
July 5.83 180.73
August 5.49 170.32
September 4.71 141.18
October 3.38 104.83
November 2.71 81.32
December 1.96 60.83
Total yearly 1545.54

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 275.77 8548.85
February 322.44 9028.23
March 395.88 12272.4
April 418.95 12568.5
May 445.7 13816.6
June 437.12 13113.7
July 461.76 14314.5
August 438.43 13591.3
September 382.56 11476.7
October 286.35 8876.95
November 238.2 7145.94
December 179.44 5562.54
Total yearly 130316

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) fals between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Saint-Majorique solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 192.57 5969.53
February 254.45 7124.66
March 350.16 10854.9
April 411.06 12331.7
May 469.62 14558.1
June 475.7 14271.1
July 495.21 15351.5
August 442.76 13725.7
September 352.65 10579.5
October 238.38 7389.88
November 175.44 5263.08
December 123.09 3815.69
Total yearly 121235

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 213.35 6613.95
February 272.35 7625.79
March 363.99 11283.7
April 417.02 12510.7
May 469.24 14546.5
June 472.22 14166.7
July 493.14 15287.4
August 446.44 13839.6
September 363.07 10892
October 251.51 7796.87
November 191.35 5740.45
December 137.06 4248.9
Total yearly 124553

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 232.24 7199.36
February 288.22 8070.23
March 375.55 11642
April 420.72 12621.7
May 466.41 14458.7
June 466.24 13987.2
July 488.48 15143
August 447.76 13880.7
September 371.32 11139.5
October 262.96 8151.86
November 205.68 6170.46
December 149.79 4643.55
Total yearly 127108

Saint-Majorique Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 249.17 7724.21
February 302.04 8457.13
March 384.8 11928.8
April 422.15 12664.4
May 461.25 14298.9
June 458.02 13740.5
July 481.39 14923
August 446.73 13848.7
September 377.39 11321.6
October 272.7 8453.63
November 218.41 6552.22
December 161.24 4998.47
Total yearly 128912

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.78% angle of incidence loss and -3.63% temperature and irradiance loss. This totals to about -15.68%%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels loose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

Murdochville