Solar Calculator Canada

Solar Power Calculator for Saint-Simon-de-Bagot, Quebec, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Saint-Simon-de-Bagot
  • GPS Coordinates: 45.7344444, -72.8733333
  • Elevation: 32 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technoloty: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Saint-Simon-de-Bagot: 39o
  • Average yearly irradiance: 1522.23 kWh/m2
  • Average yearly power output: 127822 kWh
Sun Path Saint-Simon-de-Bagot

Average yearly irradiance delivered by the Sun in Saint-Simon-de-Bagot is 1522.23/kWh/m2 at the optimal panel slope of 39o. After taking all losses into account, you can expect about 127822 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 39o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.63 81.49
February 3.12 87.32
March 4.23 131.15
April 4.97 149.18
May 5.51 170.93
June 5.47 164.01
July 5.83 180.72
August 5.49 170.18
September 4.73 141.84
October 3.36 104.05
November 2.74 82.32
December 1.9 59.04
Total yearly 1522.23

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 246.15 7630.79
February 287.65 8054.25
March 375.36 11636.2
April 421.75 12652.6
May 450.76 13973.6
June 436.65 13099.6
July 460.95 14289.5
August 437.47 13561.5
September 383.67 11510.2
October 283.84 8799.17
November 241.14 7234.15
December 173.56 5380.44
Total yearly 127822

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) fals between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Saint-Simon-de-Bagot solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 172.98 5362.51
February 227.38 6366.6
March 332.27 10300.3
April 413.74 12412.2
May 473.51 14678.8
June 473.75 14212.5
July 493.11 15286.4
August 441.56 13688.4
September 354.37 10631.1
October 237.79 7371.4
November 178.76 5362.75
December 119.66 3709.53
Total yearly 119382

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 191.63 5940.45
February 243.52 6818.47
March 345.45 10708.9
April 419.63 12588.9
May 473.17 14668.2
June 470.28 14108.5
July 490.94 15219.2
August 445.07 13797.2
September 364.71 10941.2
October 250.59 7768.33
November 194.85 5845.57
December 133.3 4132.44
Total yearly 122538

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 208.55 6465.07
February 257.82 7218.97
March 356.45 11050
April 423.26 12697.7
May 470.36 14581
June 464.31 13929.3
July 486.25 15073.7
August 446.25 13833.9
September 372.88 11186.3
October 261.74 8113.91
November 209.36 6280.67
December 145.72 4517.41
Total yearly 124948

Saint-Simon-de-Bagot Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 223.71 6935
February 270.26 7567.42
March 365.25 11322.7
April 424.6 12738.1
May 465.19 14421
June 456.11 13683.2
July 479.12 14852.9
August 445.11 13798.3
September 378.85 11365.5
October 271.19 8406.96
November 222.23 6667.03
December 156.88 4863.43
Total yearly 126621

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.79% angle of incidence loss and -4.02% temperature and irradiance loss. This totals to about -16.03%%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels loose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.