Solar Calculator Canada

Solar Power Calculator for Weir, Quebec, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Weir
  • GPS Coordinates: 45.945, -74.5494444
  • Elevation: 204 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Weir: 39o
  • Average yearly irradiance: 1527.12 kWh/m2
  • Average yearly power output: 128920 kWh
Sun Path Weir

Average yearly irradiance delivered by the Sun in Weir is 1527.12/kWh/m2 at the optimal panel slope of 39o. After taking all losses into account, you can expect about 128920 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 39o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.69 83.36
February 3.56 99.6
March 4.64 143.84
April 5.01 150.2
May 5.4 167.34
June 5.42 162.51
July 5.66 175.59
August 5.52 171.26
September 4.6 137.88
October 3.21 99.65
November 2.59 77.64
December 1.88 58.26
Total yearly 1527.12

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 253.64 7862.77
February 332.3 9304.44
March 415.82 12890.3
April 426.75 12802.6
May 441.72 13693.4
June 433.02 12990.6
July 448.65 13908.2
August 441.55 13688
September 373.76 11212.8
October 271.69 8422.49
November 227.35 6820.54
December 171.73 5323.58
Total yearly 128920

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Weir solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 183 5673.07
February 264.05 7393.42
March 368.07 11410.1
April 418.24 12547.1
May 464.55 14401
June 470.02 14100.7
July 481.53 14927.5
August 444.75 13787.2
September 345.81 10374.3
October 228.47 7082.57
November 170.81 5124.36
December 121.77 3774.93
Total yearly 120596

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 201.15 6235.8
February 282.26 7903.15
March 382.62 11861.1
April 424.24 12727.3
May 463.82 14378.3
June 466.4 13991.9
July 478.97 14848
August 448.44 13901.5
September 355.89 10676.8
October 240.65 7460.14
November 185.53 5565.76
December 134.6 4172.7
Total yearly 123723

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 217.54 6743.77
February 298.39 8354.86
March 394.78 12238.3
April 427.94 12838.3
May 460.75 14283.3
June 460.29 13808.8
July 474.01 14694.3
August 449.76 13942.4
September 363.85 10915.5
October 251.23 7788.26
November 198.73 5961.81
December 146.23 4533.23
Total yearly 126103

Weir Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 232.14 7196.35
February 312.42 8747.66
March 404.53 12540.6
April 429.32 12879.6
May 455.4 14117.4
June 451.97 13559.1
July 466.71 14468
August 448.7 13909.8
September 369.66 11089.7
October 260.19 8065.97
November 210.4 6311.94
December 156.64 4855.83
Total yearly 127742

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.79% angle of incidence loss and -3.51% temperature and irradiance loss. This totals to about -15.58%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

WarfieldBrackenForgetHazenmoreMcTaggartHewardFairlightOsageBaronsCarmichaelGarsonShamrockKendalWelwynBelle PlaineRush LakeGrand CouleeErnfoldMortlachSuccessTuxfordMarquisDisleyKeelerDubucMurdochville