Solar Calculator Canada

Solar Power Calculator for Consort, Alberta, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Consort
  • GPS Coordinates: 52.0077778, -110.7741667
  • Elevation: 733 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Consort: 43o
  • Average yearly irradiance: 1495.1 kWh/m2
  • Average yearly power output: 126777 kWh
Sun Path Consort

Average yearly irradiance delivered by the Sun in Consort is 1495.1/kWh/m2 at the optimal panel slope of 43o. After taking all losses into account, you can expect about 126777 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 43o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.77 54.79
February 2.56 71.72
March 3.51 108.7
April 5.17 154.99
May 5.87 181.97
June 5.55 166.48
July 6.35 196.86
August 5.83 180.68
September 4.99 149.85
October 3.72 115.46
November 2.26 67.75
December 1.48 45.85
Total yearly 1495.1

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 165.73 5137.68
February 238.36 6674.09
March 311.99 9671.61
April 445.07 13352.2
May 490.12 15193.8
June 450.82 13524.5
July 508.33 15758.3
August 469.99 14569.7
September 414.12 12423.7
October 322.53 9998.52
November 205.17 6154.99
December 139.29 4318.1
Total yearly 126777

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Consort solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 101.24 3138.39
February 169.61 4749.03
March 260.81 8085.09
April 422.42 12672.5
May 507.73 15739.6
June 488.14 14644.1
July 537.81 16672.3
August 460.36 14271.3
September 359.89 10796.8
October 242.95 7531.49
November 132.77 3983.17
December 81.63 2530.61
Total yearly 114814

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 115.59 3583.2
February 185.58 5196.23
March 274.37 8505.6
April 432.21 12966.3
May 510.15 15814.6
June 486.12 14583.7
July 538.27 16686.3
August 468.08 14510.5
September 375.24 11257.2
October 261.92 8119.63
November 149.01 4470.3
December 94.34 2924.63
Total yearly 118618

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 128.76 3991.49
February 200 5599.99
March 286.09 8868.64
April 439.5 13184.9
May 510.2 15816.2
June 481.88 14456.3
July 536.07 16618
August 473.32 14673.1
September 388.14 11644.2
October 278.9 8645.88
November 163.85 4915.55
December 106.03 3287.03
Total yearly 121701

Consort Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 140.71 4362.04
February 212.84 5959.43
March 295.92 9173.37
April 444.34 13330.2
May 507.81 15742.1
June 475.58 14267.5
July 531.33 16471.2
August 476.12 14759.8
September 398.56 11956.9
October 293.83 9108.67
November 177.26 5317.65
December 116.67 3616.8
Total yearly 124066

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.73% angle of incidence loss and -3.14% temperature and irradiance loss. This totals to about -15.21%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

StratfordKitchenerGuelphMississaugaOshawaQuinte WestPeterboroughBarrieOwen SoundBrockvilleOrilliaCornwallCoaticookSalaberry-de-ValleyfieldMagogSaint-Jean-sur-RichelieuGranbySherbrookeGatineauLac-M�ganticSaint-HyacintheLachuteSaint-J�r�meVal-des-SourcesPembrokeMurdochville