Solar Calculator Canada

Solar Power Calculator for Veteran, Alberta, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Veteran
  • GPS Coordinates: 52.0027778, -111.1208333
  • Elevation: 799 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Veteran: 43o
  • Average yearly irradiance: 1486.46 kWh/m2
  • Average yearly power output: 125960 kWh
Sun Path Veteran

Average yearly irradiance delivered by the Sun in Veteran is 1486.46/kWh/m2 at the optimal panel slope of 43o. After taking all losses into account, you can expect about 125960 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 43o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.72 53.35
February 2.43 68.09
March 3.45 107.06
April 5.11 153.35
May 5.87 181.97
June 5.63 168.79
July 6.34 196.66
August 5.83 180.79
September 4.98 149.27
October 3.69 114.5
November 2.25 67.42
December 1.46 45.21
Total yearly 1486.46

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 161.05 4992.44
February 225.4 6311.13
March 307.17 9522.3
April 440.02 13200.6
May 490.26 15198.2
June 457.52 13725.6
July 508.08 15750.4
August 470.53 14586.4
September 412.85 12385.6
October 320.02 9920.52
November 204.05 6121.61
December 136.94 4245.19
Total yearly 125960

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Veteran solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 98.61 3056.86
February 160.72 4500.18
March 256.07 7938.27
April 417.8 12534
May 507.76 15740.7
June 494.34 14830.3
July 536.82 16641.5
August 460.53 14276.5
September 358.87 10766.1
October 241.63 7490.61
November 132.28 3968.53
December 80.61 2499.05
Total yearly 114243

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 112.59 3490.25
February 175.85 4923.74
March 269.63 8358.39
April 427.44 12823.2
May 510.1 15813
June 492.39 14771.7
July 537.27 16655.5
August 468.26 14516.2
September 374.16 11224.7
October 260.37 8071.61
November 148.46 4453.71
December 93.1 2886.24
Total yearly 117988

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 125.42 3888.05
February 189.5 5306.06
March 281.34 8721.5
April 434.6 13037.9
May 510.06 15811.8
June 488.16 14644.8
July 535.07 16587.1
August 473.52 14679.3
September 387.01 11610.3
October 277.14 8591.37
November 163.24 4897.17
December 104.59 3242.17
Total yearly 121018

Veteran Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 137.07 4249.1
February 201.65 5646.33
March 291.18 9026.73
April 439.31 13179.4
May 507.63 15736.4
June 481.81 14454.3
July 530.34 16440.7
August 476.35 14766.8
September 397.4 11921.8
October 291.88 9048.31
November 176.59 5297.65
December 115.03 3565.91
Total yearly 123334

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.73% angle of incidence loss and -3.21% temperature and irradiance loss. This totals to about -15.26%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations: