Solar Calculator Canada

Solar Power Calculator for Chapais, Quebec, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Chapais
  • GPS Coordinates: 49.7833333, -74.85
  • Elevation: 404 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Chapais: 42o
  • Average yearly irradiance: 1386.03 kWh/m2
  • Average yearly power output: 119393 kWh
Sun Path Chapais

Average yearly irradiance delivered by the Sun in Chapais is 1386.03/kWh/m2 at the optimal panel slope of 42o. After taking all losses into account, you can expect about 119393 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 42o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.51 77.9
February 3.56 99.79
March 4.71 146.03
April 4.6 138.01
May 5.33 165.13
June 5.35 160.37
July 5.02 155.5
August 4.51 139.78
September 4 119.95
October 2.65 82.14
November 1.6 48.07
December 1.72 53.35
Total yearly 1386.03

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 245.55 7612.11
February 341.85 9571.79
March 433.46 13437.2
April 401.71 12051.3
May 444.71 13786
June 432.09 12962.6
July 401.82 12456.4
August 364.65 11304.2
September 330.76 9922.87
October 226.03 7006.93
November 141.37 4241.13
December 162.59 5040.23
Total yearly 119393

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Chapais solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 162.47 5036.65
February 254.23 7118.4
March 368.37 11419.5
April 390.66 11719.7
May 467.08 14479.6
June 469.8 14094
July 430.92 13358.5
August 370.14 11474.4
September 300.91 9027.19
October 184.84 5730.03
November 102.88 3086.39
December 104.51 3239.68
Total yearly 109784

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 181.91 5639.36
February 275.43 7711.97
March 386.07 11968.2
April 397.36 11920.8
May 467.97 14507.2
June 468.01 14040.4
July 430.22 13336.8
August 373.27 11571.4
September 310.63 9318.97
October 195.51 6060.9
November 112.1 3363.13
December 118.02 3658.58
Total yearly 113098

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 199.6 6187.62
February 294.43 8244.07
March 401.22 12437.9
April 401.91 12057.2
May 466.34 14456.4
June 463.4 13902
July 427.1 13240.2
August 374.52 11610.2
September 318.51 9555.22
October 204.87 6351.06
November 120.44 3613.12
December 130.35 4040.97
Total yearly 115696

Chapais Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 215.5 6680.63
February 311.2 8713.63
March 413.79 12827.5
April 404.29 12128.7
May 462.35 14332.8
June 456.5 13694.9
July 421.9 13079
August 373.89 11590.7
September 324.5 9735.14
October 212.89 6599.52
November 127.85 3835.46
December 141.48 4385.99
Total yearly 117604

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.87% angle of incidence loss and -1.46% temperature and irradiance loss. This totals to about -13.86%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

LadysmithEmersonPasadenaBishop's FallsOsoyoosCrestonAltonaCoronachMilk RiverCarnduffOliverKillarneyMordenCardstonBoissevainLewisporteMelitaSmooth Rock FallsKapuskasingMusgrave HarbourPrincetonPincher CreekCarmanSpringdaleEastendMurdochville