Solar Calculator Canada

Solar Power Calculator for Fernie, British Columbia, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Fernie
  • GPS Coordinates: 49.504167, -115.062778
  • Elevation: 1012 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Fernie: 37o
  • Average yearly irradiance: 1353.52 kWh/m2
  • Average yearly power output: 113055 kWh
Sun Path Fernie

Average yearly irradiance delivered by the Sun in Fernie is 1353.52/kWh/m2 at the optimal panel slope of 37o. After taking all losses into account, you can expect about 113055 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 37o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.53 47.38
February 2.39 66.93
March 2.87 89.01
April 4.33 129.86
May 5.28 163.53
June 5.22 156.57
July 6.57 203.81
August 5.96 184.9
September 4.5 134.86
October 2.87 89.11
November 1.52 45.58
December 1.35 41.98
Total yearly 1353.52

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 136.81 4241.14
February 212.49 5949.7
March 251.1 7784.1
April 373.19 11195.7
May 442.15 13706.6
June 424.95 12748.6
July 522.75 16205.1
August 476.28 14764.8
September 368.06 11041.9
October 245.17 7600.29
November 133.75 4012.45
December 122.74 3804.96
Total yearly 113055

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Fernie solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 99.76 3092.44
February 170.69 4779.21
March 225.74 6998.05
April 364.08 10922.5
May 453.32 14053
June 449.05 13471.4
July 542.11 16805.4
August 467.7 14498.6
September 335.08 10052.4
October 203.12 6296.6
November 101.85 3055.54
December 86.12 2669.87
Total yearly 106695

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 110 3409.92
February 182.7 5115.55
March 233.64 7242.77
April 369.07 11072.2
May 453.67 14063.9
June 445.82 13374.6
July 541.25 16778.7
August 473.61 14681.9
September 346.53 10395.9
October 215.38 6676.86
November 110.84 3325.28
December 96.21 2982.47
Total yearly 109120

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 119.19 3694.77
February 193.3 5412.45
March 240.18 7445.54
April 372.2 11166
May 451.94 14010.3
June 440.8 13223.9
July 538.07 16680.2
August 476.95 14785.3
September 355.87 10676.2
October 226.15 7010.5
November 118.88 3566.37
December 105.31 3264.52
Total yearly 110936

Fernie Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 127.33 3947.34
February 202.5 5669.96
March 245.35 7605.85
April 373.46 11203.9
May 448.31 13897.7
June 434.63 13038.9
July 532.01 16492.3
August 477.7 14808.6
September 363.08 10892.5
October 235.38 7296.92
November 125.96 3778.94
December 113.43 3516.27
Total yearly 112149

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.87% angle of incidence loss and -4.45% temperature and irradiance loss. This totals to about -16.47%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

LadysmithEmersonPasadenaBishop's FallsOsoyoosCrestonAltonaCoronachMilk RiverCarnduffOliverKillarneyMordenCardstonBoissevainLewisporteMelitaSmooth Rock FallsKapuskasingMusgrave HarbourPrincetonPincher CreekCarmanSpringdaleEastendMurdochville