Solar Calculator Canada

Solar Power Calculator for Steinbach, Manitoba, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Steinbach
  • GPS Coordinates: 49.525833, -96.683889
  • Elevation: 263 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technoloty: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Steinbach: 42o
  • Average yearly irradiance: 1541.29 kWh/m2
  • Average yearly power output: 131055 kWh
Sun Path Steinbach

Average yearly irradiance delivered by the Sun in Steinbach is 1541.29/kWh/m2 at the optimal panel slope of 42o. After taking all losses into account, you can expect about 131055 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 42o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.19 67.98
February 3.24 90.65
March 4.04 125.32
April 5.64 169.27
May 5.38 166.73
June 5.63 168.86
July 6.31 195.55
August 5.79 179.34
September 4.84 145.06
October 3.43 106.42
November 2.25 67.64
December 1.89 58.47
Total yearly 1541.29

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 212.47 6586.7
February 307.16 8600.34
March 363.93 11281.8
April 484.14 14524.3
May 446.42 13839.1
June 452.86 13585.9
July 502.63 15581.6
August 462.85 14348.3
September 398.52 11955.5
October 294.78 9138.22
November 202.05 6061.48
December 179.09 5551.87
Total yearly 131055

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) fals between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Steinbach solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 137.74 4269.85
February 227.43 6368.07
March 310.84 9636.09
April 463.21 13896.3
May 467.97 14507
June 493 14790
July 535.86 16611.6
August 459.7 14250.7
September 355.34 10660.1
October 232.67 7212.82
November 139.62 4188.6
December 111.58 3459.06
Total yearly 119850

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 154.93 4802.85
February 246.62 6905.46
March 325.44 10088.6
April 473.25 14197.6
May 468.76 14531.4
June 490.08 14702.3
July 535.03 16585.8
August 465.98 14445.3
September 368.57 11057
October 248.22 7694.9
November 154.18 4625.49
December 127.05 3938.58
Total yearly 123575

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 170.63 5289.63
February 263.83 7387.28
March 337.89 10474.5
April 480.54 14416.1
May 467.49 14492.3
June 484.93 14548
July 531.64 16480.9
August 469.81 14564
September 379.48 11384.3
October 262 8121.86
November 167.43 5022.78
December 141.23 4377.98
Total yearly 126560

Steinbach Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 184.81 5728.99
February 279.02 7812.69
March 348.16 10793
April 485 14550
May 464.1 14387.1
June 477.82 14334.7
July 526.14 16310.2
August 471.03 14601.9
September 388.02 11640.7
October 273.95 8492.36
November 179.31 5379.16
December 154.07 4776.06
Total yearly 128807

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.78% angle of incidence loss and -2.83% temperature and irradiance loss. This totals to about -14.97%%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels loose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

Murdochville