Solar Calculator Canada

Solar Power Calculator for Parksville, British Columbia, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Parksville
  • GPS Coordinates: 49.318056, -124.311389
  • Elevation: 23 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Parksville: 37o
  • Average yearly irradiance: 1405.18 kWh/m2
  • Average yearly power output: 116292 kWh
Sun Path Parksville

Average yearly irradiance delivered by the Sun in Parksville is 1405.18/kWh/m2 at the optimal panel slope of 37o. After taking all losses into account, you can expect about 116292 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 37o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.17 36.15
February 2.5 70.12
March 3.35 103.83
April 4.8 144.15
May 5.52 171.27
June 5.54 166.11
July 6.55 202.91
August 6.09 188.64
September 4.82 144.69
October 2.81 87.07
November 1.81 54.4
December 1.16 35.84
Total yearly 1405.18

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 98.61 3056.92
February 216.45 6060.49
March 288.27 8936.47
April 407.37 12221.1
May 457.3 14176.2
June 451.7 13551.1
July 524.6 16262.6
August 488.93 15156.7
September 394.62 11838.5
October 235.53 7301.49
November 155.5 4664.91
December 98.89 3065.66
Total yearly 116292

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Parksville solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 74.51 2309.91
February 172.66 4834.42
March 258.64 8017.99
April 394.18 11825.5
May 469.07 14541.2
June 477.38 14321.4
July 546.17 16931.3
August 480.41 14892.7
September 355.44 10663.2
October 195.95 6074.49
November 115.62 3468.66
December 70.38 2181.7
Total yearly 110062

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 81.14 2515.41
February 184.98 5179.51
March 268.16 8312.97
April 400.79 12023.6
May 470.18 14575.5
June 474.85 14245.6
July 545.33 16905.3
August 486.83 15091.7
September 368.36 11050.9
October 207.43 6430.34
November 126.58 3797.45
December 78.13 2421.97
Total yearly 112550

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 87.15 2701.53
February 195.98 5487.3
March 276.12 8559.57
April 405.28 12158.4
May 469.08 14541.4
June 470.3 14109.1
July 541.93 16799.8
August 490.62 15209.1
September 378.98 11369.4
October 217.51 6742.72
November 136.5 4095.11
December 85.19 2640.93
Total yearly 114414

Parksville Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 92.5 2867.52
February 205.6 5756.84
March 282.48 8756.8
April 407.64 12229.1
May 465.51 14430.7
June 463.93 13917.8
July 536.35 16626.8
August 491.7 15242.8
September 387.24 11617.1
October 226.15 7010.69
November 145.36 4360.78
December 91.55 2837.93
Total yearly 115655

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.85% angle of incidence loss and -5.35% temperature and irradiance loss. This totals to about -17.24%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations: