Solar Calculator Canada

Solar Power Calculator for Weyburn, Saskatchewan, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Weyburn
  • GPS Coordinates: 49.6609833, -103.8526306
  • Elevation: 563 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technoloty: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Weyburn: 42o
  • Average yearly irradiance: 1615.5 kWh/m2
  • Average yearly power output: 136968 kWh
Sun Path Weyburn

Average yearly irradiance delivered by the Sun in Weyburn is 1615.5/kWh/m2 at the optimal panel slope of 42o. After taking all losses into account, you can expect about 136968 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 42o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.23 69.04
February 3.09 86.4
March 3.93 121.76
April 5.56 166.77
May 5.87 181.96
June 5.92 177.6
July 6.65 206.15
August 6.09 188.78
September 5.39 161.76
October 3.91 121.29
November 2.58 77.34
December 1.83 56.67
Total yearly 1615.5

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 211.42 6553.97
February 289.59 8108.58
March 350.59 10868.4
April 477.76 14332.7
May 488.08 15130.4
June 479.12 14373.7
July 530.13 16433.9
August 487.04 15098.3
September 444.24 13327.2
October 337.16 10451.8
November 232.44 6973.17
December 171.49 5316.13
Total yearly 136968

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) fals between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Weyburn solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 135.07 4187.2
February 210.07 5882.05
March 298.97 9267.97
April 457.39 13721.6
May 512.19 15878
June 522.72 15681.6
July 564.68 17505.2
August 482.64 14961.8
September 392.32 11769.7
October 261.74 8113.95
November 158.71 4761.38
December 105.55 3271.94
Total yearly 125002

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 152.51 4727.73
February 228.91 6409.39
March 313.12 9706.78
April 467.22 14016.5
May 513.75 15926.3
June 520.42 15612.7
July 565.12 17518.6
August 489.29 15167.9
September 407.82 12234.5
October 280.31 8689.57
November 175.85 5275.58
December 120.45 3734.06
Total yearly 129020

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 168.42 5221.06
February 245.83 6883.11
March 325.21 10081.4
April 474.36 14230.7
May 512.45 15885.9
June 515.46 15463.8
July 561.95 17420.5
August 493.19 15289
September 420.68 12620.5
October 296.81 9200.96
November 191.43 5742.86
December 134.1 4157.09
Total yearly 132197

Weyburn Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 182.78 5666.25
February 260.8 7302.42
March 335.19 10390.8
April 478.78 14363.5
May 508.47 15762.5
June 507.55 15226.5
July 555.74 17227.9
August 494.35 15324.7
September 430.88 12926.3
October 311.18 9646.67
November 205.4 6162.06
December 146.46 4540.11
Total yearly 134540

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.67% angle of incidence loss and -3.21% temperature and irradiance loss. This totals to about -15.22%%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels loose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

Murdochville