Solar Calculator Canada

Solar Power Calculator for Les Buissons, Quebec, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Les Buissons
  • GPS Coordinates: 49.1022222, -68.3852778
  • Elevation: 15 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Les Buissons: 41o
  • Average yearly irradiance: 1432.75 kWh/m2
  • Average yearly power output: 123960 kWh
Sun Path Les Buissons

Average yearly irradiance delivered by the Sun in Les Buissons is 1432.75/kWh/m2 at the optimal panel slope of 41o. After taking all losses into account, you can expect about 123960 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 41o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.15 66.75
February 3.26 91.37
March 4.28 132.55
April 4.87 145.98
May 5.29 163.88
June 5.34 160.23
July 5.47 169.49
August 5.04 156.39
September 4.31 129.41
October 3.13 96.93
November 2.21 66.21
December 1.73 53.57
Total yearly 1432.75

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 206.64 6405.83
February 309.23 8658.33
March 391.5 12136.5
April 427.97 12839.2
May 448.95 13917.6
June 440.92 13227.7
July 445.65 13815.1
August 413.39 12815.2
September 361.38 10841.3
October 270.76 8393.42
November 197.27 5918.09
December 161.03 4992.03
Total yearly 123960

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Les Buissons solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 140.33 4350.21
February 234.45 6564.56
March 338.83 10503.6
April 415.03 12451
May 469.7 14560.6
June 476.42 14292.5
July 473.74 14686.1
August 413.29 12812.1
September 326.67 9800.06
October 218.11 6761.44
November 139.61 4188.21
December 104.44 3237.62
Total yearly 114208

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 156.03 4836.98
February 252.98 7083.5
March 353.79 10967.6
April 422.56 12676.8
May 470.38 14581.7
June 473.89 14216.7
July 472.86 14658.7
August 418.05 12959.5
September 337.75 10132.6
October 231.69 7182.34
November 153.43 4603.04
December 117.68 3648.14
Total yearly 117548

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 170.37 5281.5
February 269.58 7548.14
March 366.5 11361.4
April 427.78 12833.3
May 468.89 14535.6
June 469.2 14076.1
July 469.92 14567.4
August 420.57 13037.7
September 346.78 10403.3
October 243.66 7553.52
November 165.99 4979.79
December 129.84 4024.97
Total yearly 120203

Les Buissons Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 183.3 5682.22
February 284.19 7957.27
March 376.89 11683.7
April 430.47 12914.2
May 465.53 14431.3
June 462.62 13878.5
July 464.92 14412.5
August 420.85 13046.3
September 353.7 10611
October 253.99 7873.72
November 177.24 5317.22
December 140.86 4366.59
Total yearly 122175

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.81% angle of incidence loss and -1.09% temperature and irradiance loss. This totals to about -13.48%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

ValparaisoBeattyRidgedaleWasecaMinburnWeirdaleLavoySpring LakeEntwistlePort ColborneThoroldCounty of BrantLambton ShoresBurlingtonCambridgeWaterlooBramptonVaughanPrince EdwardKawartha LakesHuntingdonSuttonBedfordDunhamCowansvilleMurdochville