Solar Calculator Canada

Solar Power Calculator for Sainte-Hedwidge-de-Roberval, Quebec, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Sainte-Hedwidge-de-Roberval
  • GPS Coordinates: 48.481389, -72.365833
  • Elevation: 278 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Sainte-Hedwidge-de-Roberval: 42o
  • Average yearly irradiance: 1459.46 kWh/m2
  • Average yearly power output: 125212 kWh
Sun Path Sainte-Hedwidge-de-Roberval

Average yearly irradiance delivered by the Sun in Sainte-Hedwidge-de-Roberval is 1459.46/kWh/m2 at the optimal panel slope of 42o. After taking all losses into account, you can expect about 125212 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 42o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.82 87.39
February 3.77 105.44
March 4.64 143.8
April 4.75 142.38
May 5.36 166.31
June 5.35 160.64
July 5.23 162.02
August 4.87 150.94
September 4.26 127.74
October 2.95 91.5
November 2.06 61.85
December 1.92 59.43
Total yearly 1459.46

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 272.24 8439.59
February 357.74 10016.8
March 422.47 13096.6
April 411.76 12352.8
May 445.07 13797.1
June 432.1 12963.1
July 417.5 12942.4
August 392.47 12166.5
September 350.84 10525.3
October 252.76 7835.67
November 183.66 5509.76
December 179.56 5566.51
Total yearly 125212

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Sainte-Hedwidge-de-Roberval solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 182.03 5643.06
February 269.76 7553.19
March 365.24 11322.6
April 402.76 12082.8
May 469.08 14541.3
June 471.21 14136.4
July 449.71 13941
August 396.86 12302.7
September 319.99 9599.64
October 207.45 6431.06
November 132.62 3978.53
December 117.43 3640.2
Total yearly 115173

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 203.18 6298.52
February 291.31 8156.76
March 381.41 11823.8
April 409.06 12271.9
May 469.41 14551.8
June 468.28 14048.5
July 448.3 13897.3
August 400.41 12412.6
September 330.21 9906.24
October 219.26 6797.19
November 144.85 4345.44
December 131.96 4090.79
Total yearly 118601

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 222.44 6895.73
February 310.6 8696.93
March 395.14 12249.3
April 413.19 12395.7
May 467.48 14492
June 463.61 13908.2
July 444.55 13781.1
August 401.88 12458.2
September 338.44 10153.3
October 229.62 7118.16
November 155.91 4677.3
December 145.24 4502.49
Total yearly 121328

Sainte-Hedwidge-de-Roberval Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 239.78 7433.3
February 327.59 9172.49
March 406.39 12598.1
April 415.13 12453.9
May 463.12 14356.7
June 456.35 13690.5
July 438.59 13596.4
August 401.28 12439.8
September 344.67 10340
October 238.48 7392.77
November 165.77 4973.05
December 157.23 4874.13
Total yearly 123321

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.83% angle of incidence loss and -1.9% temperature and irradiance loss. This totals to about -14.21%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations: