Solar Calculator Canada

Solar Power Calculator for Aquaforte, Newfoundland and Labrador, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Aquaforte
  • GPS Coordinates: 47.0080555, -52.9563889
  • Elevation: 6 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Aquaforte: 37o
  • Average yearly irradiance: 1260.33 kWh/m2
  • Average yearly power output: 108189 kWh
Sun Path Aquaforte

Average yearly irradiance delivered by the Sun in Aquaforte is 1260.33/kWh/m2 at the optimal panel slope of 37o. After taking all losses into account, you can expect about 108189 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 37o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.57 48.72
February 2.21 61.75
March 3.06 94.77
April 4.36 130.71
May 4.72 146.35
June 4.92 147.63
July 5.1 158.15
August 4.6 142.56
September 4.14 124.2
October 2.89 89.46
November 2.15 64.59
December 1.66 51.43
Total yearly 1260.33

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 142.13 4406.09
February 199.78 5593.82
March 274.2 8500.1
April 382.92 11487.5
May 405.71 12576.9
June 414.88 12446.5
July 420.66 13040.4
August 377.64 11707
September 346.87 10406
October 248.69 7709.34
November 190.02 5700.52
December 148.86 4614.66
Total yearly 108189

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Aquaforte solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 105.95 3284.43
February 164.82 4615.01
March 250.17 7755.36
April 375.54 11266.2
May 423.14 13117.3
June 442.07 13262
July 442.52 13718.1
August 379.1 11752
September 321.03 9630.94
October 210.96 6539.64
November 143.84 4315.3
December 104.98 3254.23
Total yearly 102511

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 115.84 3591.12
February 174.87 4896.29
March 258.19 8003.97
April 380.69 11420.7
May 422.35 13092.9
June 438.85 13165.4
July 440.87 13667.1
August 382.02 11842.7
September 330.25 9907.42
October 222.07 6884.13
November 156.54 4696.3
December 116.79 3620.59
Total yearly 104789

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 124.82 3869.49
February 183.74 5144.75
March 264.75 8207.1
April 383.78 11513.3
May 419.76 13012.6
June 433.7 13011
July 437.13 13551.2
August 383.05 11874.4
September 337.53 10126
October 231.76 7184.52
November 168.03 5040.96
December 127.61 3956.02
Total yearly 106491

Aquaforte Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 132.85 4118.46
February 191.41 5359.41
March 269.8 8363.78
April 384.8 11544.1
May 415.3 12874.3
June 427.04 12811.1
July 431.34 13371.5
August 382.13 11845.9
September 342.86 10285.7
October 239.98 7439.5
November 178.27 5347.98
December 137.39 4259.08
Total yearly 107621

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -3.04% angle of incidence loss and -1.63% temperature and irradiance loss. This totals to about -14.16%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

Saint-PhilippeSaint-AugustinSaint-Adolphe-de-DudswellPointe-au-Ch�neSainte-ScholastiqueSainte-MoniqueSaint-Louis-de-TerrebonneSaint-JanvierSaint-Pierre-de-WakefieldSainte-Jeanne-d'ArcSaint-Simon-de-BagotLakefieldLadysmithLost RiverSaint-JosephSaints-MartyrsLesageDavidsonShawbridgeMontfortSaint-MajoriqueWeirSainte-VictoireSaint-David-d'YamaskaVimy-RidgeMurdochville